The air filter is mainly used for clean air-conditioning system or air supply of purification equipment. According to the grade, it can be divided into primary filter (G1~G4), medium efficiency filter (M5~M6, F7~F9), high efficiency filter (E10~E12, H13~H14), ultra high efficiency filter (U15~U17) ). According to the structure, it can be divided into plate type, bag type, W type (box type W type), with partition, without partition, and tank without partition, etc.
  • Sub high efficienc separated filter1
  • High efficiency ultra high efficiency separated1
  • W type filter1
  • Bag type filter1
Sub high efficienc separated filter1

Sub high efficienc separated filter1

High efficiency ultra high efficiency separated1

High efficiency ultra high efficiency separated1

W type filter1

W type filter1

Bag type filter1

Bag type filter1

Product description
Parameters

Generally, the primary filter can effectively filter out particles above 5um, and the medium-efficiency filter can effectively filter out particles above 1um, which can prevent particles from depositing on the surface of measuring elements such as temperature and humidity sensors, heat exchange elements, and air ducts, and improve system performance. At the same time, it protects the back-end high efficiency filter and extends its service life. High-efficiency filters are mostly used for terminal purification, and the gas is filtered directly into the cleanroom or clean space to maintain a clean environment to meet the requirements of use.

1. Air filter for general ventilation

(1) Bag-type air filter

The primary effect bag-type air filter is mainly used to filter out dust particles ≥5μm in the air-conditioning system, protect the medium-efficiency filter, and extend its service life.

The medium-efficiency bag-type air filter is mainly used to filter out dust particles ≥1μm in the air-conditioning system, protect the subsequent sub-high-efficiency or high-efficiency filters, and extend their service life.

Characteristics of bag-type air filter

  • Bag structure, increase the filter area
  • A variety of welding program to meet the welding requirements of different filter materials
  • The filter bag is welded in line, with high strength, preventing the risk of leakage;
  • High consistency of filter bag parameters, improving product stability;
  • Bag-type air filter frame material: galvanized sheet/aluminum profile;
  • Bag-type air filter aluminum: PP/PET composite fiber;
  • Operating conditions: the highest 100%RH, 60℃;

(2) Panel air filter

                           

The panel air filter is mainly used to filter out dust particles above 5μm in the air conditioning system, protect the medium-efficiency filter, and extend its service life. The characteristics of the panel air filter are as follows:

  • Small size and compact structure;
  • Two forms of folding net and mother-child frame;
  • Generally, it is the initial effect, but it can be the middle effect;
  • Plate air filter frame material: galvanized sheet/aluminum profile/cardboard frame;
  • Plate air filter aluminum: PP/PET composite fiber;
  • Operating conditions: the highest 100%RH, 60℃;

(3) W-type air filter

The W-type air filter uses thinner filter paper without partitions to form multiple V-types, which effectively enlarges the filtering area and reduces the structural resistance of the filter. The air volume is large, the resistance is small, and the service life is long. The characteristics of the W-type air filter are as follows:

  • Two types of box type and W type;
  • Large filtering area, suitable for large air volume;
  • F7-H14 various levels are optional;
  • W-type air filter frame material: ABS/galvanized sheet/stainless steel/aluminum sheet;
  • W-type air filter spacer: hot melt glue;
  • W-type air filter filter paper: glass fiber filter paper;
  • W-type air filter seal: PU sealing strip;
  • Operating conditions: Max80%, 80℃;

 

2. Sub-high-efficiency/high-efficiency/ultra-high-efficiency filter

(1) Sub-high efficiency partition filter

                

Sub-high efficiency partition filters are used in clean rooms, commercial and industrial ventilation and air conditioning systems, and ventilation and air conditioning systems with high fire protection requirements or high ventilation temperatures.

a. charateristic

  • Aluminum partition, frame can be provided without flange, single flange, double flange, flange thickness 20mm;
  • Using ultra-fine glass fiber filter paper;
  • With partition design, high efficiency, low resistance and large dust holding capacity;
  • Suitable for variable air volume system;
  • Efficiency options: 85%@0.3μm(H10), 95%@0.3μm(H11), 99.5%@0.3μm(H12)(EN1822);

b. usage

  • For clean rooms, commercial and industrial ventilation and air-conditioning systems;
  • Ventilation and air-conditioning system in high humidity environment;
  • Variable air volume ventilation and air-conditioning system;
  • Ventilation and air-conditioning system with tight installation space;
  • Ventilation and air conditioning systems with high fire protection requirements or high ventilation temperature;
  • Widely used in clean rooms and other areas where air cleanliness is strictly required;

(2) Sub-high efficiency filter without partition

Sub-high-efficiency non-baffle filters are used in clean rooms, commercial and industrial ventilation and air conditioning systems, ventilation and air conditioning systems in high humidity environments, etc.

a. charateristic

  • No partition design reduces operating costs;
  • Wide application range, compact structure, saving storage space;
  • Ultra-thin design, saving installation space;
  • Efficiency options: 85%@0.3μm(H10), 95%@0.3μm(H11), 99.5%@0.3μm(H12)(EN1822);

b. usage

  • For clean rooms, commercial and industrial ventilation and air-conditioning systems;
  • Ventilation and air-conditioning system in high humidity environment;
  • Variable air volume ventilation and air-conditioning system;
  • Ventilation and air-conditioning system with tight installation space;

(3) High-efficiency/ultra-high-efficiency filter without partition

a. characteristic

  • No partition design to reduce operating costs;
  • Wide application range, compact structure, saving storage space;
  • Ultra-thin design, saving installation space;
  • Efficiency: 99.97%@0.3μm(H13), 99.99%@0.3μm(H14), 99.999%@0.3μm(U15)(EN1822);

b. usage:

  • High temperature and variable air volume vent air conditioning system (medium-efficiency, sub-high-efficiency filter without clapboard);
  • Used in the high-efficiency air supply outlet of the clean room of the pharmaceutical factory;
  • Local purification equipment such as laminar flow hoods, clean benches, biological safety cabinets, pass box, etc.;
  • Purification plant FFU products with high-efficiency filters

(4) High efficiency/ultra-high-efficiency filter with partition

         

a. characteristic:
The high-efficiency/ultra-high-efficiency separator filter adopts a separator-type design, and the corrugated separator can accurately maintain the distance between the pleats, and maximize the use of the filter material with the least resistance. 180 pleats on both sides of the filter material are folded into a wedge-shaped pleat layer. When the filter material is bent, there are two indentations to make it form a wedge-shaped box pleated layer at the end of the partition. The wedge-shaped box pleated layer can be Prevent damage to the filter material.

b. usage:

It is mainly suitable for terminal filtration of various special clean rooms and various local purification equipment, such as clean bench laminar flow hood and other environmental air purification;

c. performance:

  • Frame: aluminum alloy or galvanized iron and stainless steel frame;
  • Filter material: ultra-fine glass fiber paper;
  • Separation material: rubber paper or aluminum foil;
  • EN779 level: H10, H11, H12, H13, H14;
  • DIN 53438 flame retardant standard: F1;
  • Final resistance: (recommended) 450Pa;
  • Maximum air volume: 125% of the rated air volume;
  • Temperature resistance: 80℃;
  • Filter size: According to the actual requirements of the customer, the reference thickness of the aluminum profile; 120mm, 150mm, 220mm, 295mm;
  • Limit size: width≤1220mm, length≥1220mm, thickness 50~300mm.
Keyword:
HEPA filter
HVAC system
high efficiency filter
Cleanroom Air Filtration
clean room hepa filters
We could not find any corresponding parameters, please add them to the properties table
Next

Related Products

Products that maybe needed

Message

Looking for a worry-free, labor-saving, and cost-saving solution? Want to get product catalogs and price lists? Please fill out the form below or send an email and our professional team will contact you within 12 hours.

留言应用名称:
客户留言
describe:
验证码

CONTACT

Shanghai Office: NO211, North Fute Road, Pudong area, Shanghai, China, 200131

Changsha Office: Room 23069, Block 6, Forte Star Shine World, Yuhua District, Changsha, Hunan province

Factory 1: Hunan Marya Technology Co., Ltd. Address: No. 7 Plant, SANY Industrial Park, No. 1, SANY Road, Changsha Pilot Free Trade Zone, Hunan Province, China, 410100

Factory 2: No 555, Yupan Road, Weitang Town, Xiangcheng District, Suzhou, Jiangsu Province, China

Factory 3: 15-A, Venture Capital Industrial Square, Yanghe Road, Suzhou Industrial Park

Tel:+86-13507449007

E-Mail:info@marya.com.cn

SEARCH

Search
Search

Copyright © 2020 Shanghai Marya Pharmaceutical Engineering & Project Co., Ltd    沪ICP备2021002344号-1

Powered by 300.cn changsha