Cartridge Bottle
Borosilicate glass sleeves for pen-type syringes are commonly known as cartridges; cartridges are similar to syringes without push rods, which are equivalent to "bottomless bottles".The front of the bottle is equipped with an injection needle protected by a rubber seal, the bottle mouth is sealed with a rubber stopper aluminum cap, and the tail is sealed with a rubber piston.
- Product Description
- Technical Features
- Technical Parameters
- Optional Systems
- Application Scenarios
- Video
-
1. Overview
The cartridge is placed in a reusable cartridge or injection pen for use, and the liquid medicine does not come into contact with any part of the syringe during use.Cartridge injection has a wide range of applications and can be used in the following fields: anti-biochemical emergency, hemostasis and pain relief, cardiac emergency, insulin, detoxification, antipyretic and analgesic, anesthesia and sedation, antibiotics, interferon, transfer factor, hangovers, etc.
2. Product introduction
- Specification: 1-5ML; Executive standard number: YBB00112004-2015 (with injection needle);
- Product material: medium borosilicate glass tube;
- High structural strength for maximum drug protection.
- Safer handling of toxic drugs.
- Cost savings by reducing the number of breakages and defects in use.
- Product customization is available according to specific auto-injector requirements.
3. The specification size of the cartridge bottle

Unit: millimeter (mm)
d1
d2
d3
min.
d4
d5
d6
h1
h2
size
deviation
Size
deviation
size
deviation
size
deviation
size
deviation
size
deviation
size
deviation
8.65
±0.1
6.85
±0.1
6.55
7.15
±0.2
5.5
±0.35
3.15
±0.2
5.0
±0.2
2.9
±0.1
10.85
8.65
8.35
10.95
±0.15
9.25
8.95
11.60
9.65
9.35
14.00
12.00
±0.15
11.65
9.5
7.6
4.5
±0.15
14.45
11.85
11.50
18.25
16.05
15.50
The lengths of L1 and L2 can be customized according to customer needs;

1.8ml Cartridge size
Specifications
Average (mm)
Deviation
Diameter
Outer diameter of bottle
8.65
±0.1
Bottle inner diameter
6.85
Cartridge inlet
≥6.5
Outer diameter of bottle mouth
7.15
±0.2
Inner diameter of bottle mouth
3.15
±0.15
neck
5.5
±0.25
High
Full height
62
±0.3
Bottle mouth height
2.9
±0.1
Bottom of neck to top
5
±0.2
Production Bases
Successful Projects in 70 Countries
Loyal Clientele
Invited to the Embassy of the United Republic of Tanzania in Guangzhou to discuss projects
Tanzanian Vice President Visits Marya Pharmaceutical EPC Project
NBA (Zimbabwe National Biotechnology Authority) conducts FAT at MARYA’s Factory
NOVO NORDISK client Visit
Clients visit the factory's liquid preparation system
Argentine client visits for FAT in MARYA
INTERESTED IN MARYA?
Get In Touch With Us.
We Will Be Happy To Discuss Our Solutions And Services With You.
Contact Now
Full-process Consulting Services
Whether you are preparing to build a new pharmaceutical factory, build a cleanroom that complies with local GMP regulations, or purchase pharmaceutical equipment to develop a new production line, whether it is a separate cleanroom or pharmaceutical machine project, or a one-stop solution, Marya's professional teams in the fields of pharmaceutical technical process, process equipment, decoration engineering, HVAC engineering, pipeline engineering, utility equipment, intelligent automatic control systems, project cost and other fields can provide you with full-process technical consulting services, and solve your needs one-on-one.
2D/3D Design Modeling Services
Marya project design team is composed of professional CAD and BIM engineers with more than 20 years of comprehensive industry experience and can provide you with comprehensive design services, including but not limited to process layout drawings, technical process charts, 3D models and animations, air conditioning system scheme design, construction drawing design, plant/pharmaceutical machine layout drawings, etc.
Machine Customization Services
Based on the individual needs of clients in different countries, Marya helps you clarify specific needs, match appropriate models, and customize one stop filling solutions for sterile small-volume preparations, large-volume injections, oral liquids/syrups, solid preparations, etc.
Validation Services (FAT/SAT)
Marya will appoint an engineer with rich project management experience as the person in charge, who will be fully responsible for project management and liaison work. After the equipment is manufactured, our engineers and the buyer's representatives will participate in the FAT test. After the equipment arrives at the buyer's site, it will be installed and debugged. After the equipment reaches optimal operation, the buyer will conduct SAT testing and inspection.
Key words:
Cartridge Bottle
Cartridge Syringe
Cartridge Filling Machine
Previous:
Contact MARYA Engineers to Claim Your Free GMP compliant Aseptic Pharmaceutical Production Line Solution
Looking for a worry-free, labor-saving, and cost-saving solution? Want to get product catalogs and price lists? Please fill out the form below or send an email and our professional team will contact you within 12 hours.
CONTACT INFO
NO211, North Fute Road, Pudong area, Shanghai, China, 200131